Hvac Duct Sizing Rule Of Thumb
V 2 v 1 a 1 a 2.
Hvac duct sizing rule of thumb. The furnace s british thermal units btus will help calculate the size it needs. After designing a multitude of hvac systems for all sorts of buildings you should be able to the calculator uses the building square footage building usage type and building shape to. Also if you re interested in learning even more here s a free download for you. They are only typical values which should be verified for each application.
Remember when hvac contractors use rules of thumb to size air conditioners they usually pick a number between 400 and 600 square feet per ton. 600 fpm is recommended for low restriction and noise. Conditioner repair near me duct cfm calculation formula duct size per ton duct sizing and calculation methods duct velocity rule of thumb ductwork sizing chart hvac duct design example near me return air duct size 5 ton unit. The following sizes assume no more than 4 flexible duct compression.
Click here to learn hvac duct sizing rule of thumb. Regarding the long duct runs you see in the schematic at the top of this article we do that for a good reason. Note that not a single one of our load calculations was as low as the high end of their range. Do not assume these values to be laws.
John yes there are indeed other methods. Most cases the air in a duct is assumed to be incompressible an assumption that overlooks the change of air density that occurs as a result of pressure loss and flow in the ductwork. Duct sizing rules of thumb. It takes years of experience to be able to quickly select an hvac system type size the hvac system and cost the hvac system with limited information.
Standardized emcs energy savings calculations 20 3mb pdf general information air movement 6 ach 1 cfm ft2 ventilation rate 5 cfm person fan energy 1000 1500 cfm hp electric motors 0 75 kw hp. Use the duct calculator to find the velocity of the air at the size determined by the friction rate and increase the size if the velocity is greater than 700 fpm. Size to 400 cfm per nominal ton. And yes the majority of hvac systems don t get proper design instead relying on rules of thumb.
In order for your forced air furnace to work properly you have to have the right sizes of duct vents in each room expelling air. Yes extra duct surface area hurts when the ducts are in unconditioned space. Here s what our data show. As an industry we ve been taught from the outset that sizing hvac systems is a matter of using the 500 rule of thumb.
In ductwork the law of conservation of mass means a duct size can be recalculated for a new air velocity using the simple equation. For starters those of us who have been servicing and installing residential air conditioning systems for the last two or three decades pretty much had it figured out that if we sized systems at the ratio of one ton for.